Skip to main content

Style Options

Layout Style

Colors schema

Direction

+254751021020 kenyachem @ gmail.com Search :

BoilerGuard SCP

bundle

1.10 Phenanthroline Monohydrate - RXSOL-60-6120-250
Degreaser Bio Degradable - RXSOL-10-1102-025
Chembreak QUICK SEPARATING DEGREASER - RXSOL-20-2006-025
Degreaser Citrus Deodorizer ( Cleaner cum Bad odour controller ) - RXSOL-10-1723-025
Degreaser Conc. Double Strength Detergent - RXSOL-10-1716-025
Degreaser for HEAVY SOIL - RXSOL-10-1732-025
Degreaser Concentrated - RXSOL-10-1733-025
Citrus Auto Degreaser C.A.D - RXSOL-10-1734-025
Degreaser Electrical Non Flame - RXSOL-10-1738-025
Degreaser Dual strength Surfactant - RXSOL-10-1739-025
BoilerGuard SCP
Also known as

NALCO Synerpon SCP

SKU
RXSOL-42-5012-025
SUPPLY LOCATION:
Locations

BOW RXSOL manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of BOW RXSOL at a competitive price from us. We have ready stock of BOW RXSOL in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Hashtags
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride
Variations

RXSOL BoilerGuard SCP Catalyst is a dry catalytic treatment designed to enhance the performance and reaction rate of sulfite/bisulfite-based oxygen scavenger programs used in boiler feedwater systems.

The product is formulated to promote more efficient removal of dissolved oxygen from boiler feedwater, helping reduce the risk of oxygen-induced corrosion and pitting in feedwater lines, boiler components and associated steam-system equipment.

It is particularly suitable for use as a catalyst/booster in sulfite or bisulfite oxygen-scavenging programs, rather than being regarded as a standalone replacement for the primary oxygen scavenger. Catalyzed sulfite systems are established boiler-water treatment approaches for accelerating oxygen removal.

Remarks

Key Features of BoilerGuard SCP

  • Catalyzes sulfite/bisulfite oxygen removal
  • Promotes faster dissolved-oxygen reduction
  • Helps protect boiler systems against oxygen corrosion
  • Supports control of pitting corrosion
  • Water-soluble dry formulation
  • Easy to dose through a prepared treatment solution
  • Suitable for integration into existing oxygen-scavenger programs
Note
Recommended Applications
 
RXSOL BoilerGuard SCP Catalyst is intended for:
  • Boiler feedwater treatment
  • Oxygen scavenger catalyst programs
  • Sulfite oxygen scavenger systems
  • Bisulfite oxygen scavenger systems
  • Industrial steam boilers
  • High-pressure boiler systems, subject to system-specific chemistry evaluation
  • Feedwater corrosion-control programs
 
Chemical oxygen removal is generally used as a final stage of oxygen control after mechanical deaeration where applicable. Effective boiler programs require control of dissolved oxygen, feedwater chemistry and chemical residuals.

 

Property Typical Value
Appearance Free-flowing powder
Colour White to off-white / pale coloured*
Odour Odourless or slight characteristic odour
pH, 1% aqueous solution Alkaline
Solubility in Water Fully soluble / readily soluble
Physical Form Dry powder
Shelf Life 12 months*
The formulation is based on a controlled blend of alkaline and catalytic components.
 
Typical chemical system:
 
Sodium carbonate
Cobalt salt / cobalt sulphate catalyst
Sodium pyrophosphate
 
The exact formulation ratio is proprietary and should be established through formulation and QC validation before commercial release.

A typical starting treatment range is:

10-30 ppm of product in boiler feedwater, depending on dissolved oxygen concentration and the operating conditions of the boiler system.

System Condition Suggested Starting Range
Low dissolved oxygen 10 ppm
Normal oxygen load 10–20 ppm
Elevated oxygen load 20–30 ppm
Severe oxygen ingress Optimize by testing

The actual dosage should be determined based on:

  • Dissolved oxygen concentration
  • Boiler operating pressure
  • Feedwater temperature
  • Deaerator performance
  • Sulfite/bisulfite residual
  • Required oxygen residual
  • Boiler water chemistry
  • Feedwater flow rate

Benefits of using RXSOL BoilerGuard SCP

Improved Oxygen Removal
Enhances the reaction efficiency of sulfite/bisulfite oxygen scavengers.
 
Corrosion Protection
Helps reduce dissolved-oxygen-related corrosion and pitting.
 
Boiler System Protection
Supports protection of feedwater lines, boiler tubes and associated equipment.
 
Treatment Optimization
Can improve the performance of an existing sulfite/bisulfite treatment program without requiring a completely different oxygen-scavenging chemistry.
Related Product:

 

X

Request for Quote and Get Heavy Discount on Price