Air Cooler Scale Dissolver Air Cooler Cleaner Sea Water SIDE specialized product for CLEANING of SCALE from SEA WATER side. We are manufacturer and supplier of AIR COOLER cleaner in Mumbai, Rabale, Mahape, Turbha, Maharastra, Surat Hazira Kandla Mundra, Gandhidham, Gujrat, Kolkata Haldia Paradip, Visakhapatnam, Gangavaram Kakinada, Chennai Ennore, JNPT in INDIA and Dubai, Sharjah, Ajman, Abudhabi, Fujairah UAE GULF, Ruwi Gala, Barka, Muscat Oman, Sudan, Yemen, NAirobi, Kenya CANADA
Air Cooler Scale Remover Cleaner Sea Water SIDE is specialized product to dissolve water scale smoothely. We are manufacturer and supplier of Air Cooler Cleaner Sea Water SIDE.
RXSOL-54-1048-020 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module RX cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008--DC Boilers, See RX cleansers Practical Application Manual
Dirt in tubes of seawater side
White scales attached on the seawater side of air coolers of many vessels. We found that in most cases, the main component of the scales is calcium carbonate and there is also a small amount of calcium sulfate. Therefore in most cases, if you dissolve the calcium carbonate the scales will be removed.
However, if the amount of scales is large enough to block the tube, the cylindrical scale will usually have calcium carbonate on the outside (the side that is in contact with tube) and calcium sulfate in the center (part that seawater passes through). Calcium sulfate is easier to be formed when the temperature goes higher.
When the amount of scales increases, the contact area of scale and cleaner is very small and a longer time of dissolution is required. Calcium sulfate cannot be dissolved by an acid cleaner.
RXSOL-54-1048-020 is a powerful dissolving agent of calcium carbonate. Therefore, it is better to use RXSOL-54-1048-020 to do circulating cleaning at an early stage before the scales build up and block the tube, or regular cleaning is recommended as well. It is impossible to do a circulating cleaning when the tube is completely blocked.
while Dirt attached on air-side fins of air coolers are a mix of carbonaceous particles such as soot and oil mist of unburned fuel components can be clean by RXSOL-16-0009-025. ( www.rxmarine.com/air-cooler-cleaner-25-ltr )
Carbonaceous particles can be removed by alkaline cleaners and oil mist can be removed by oil based cleaners. However, it is very difficult to remove the mix of these substances. If you use an alkaline cleaner, oil will repel the water based alkaline cleaner; if you use oil based cleaner, carbonaceous particles will get in the way and stop oil from being removed.
This cleaners designed to remove both carbonaceous and oil simultaneously. An effective cleaning method is to immerse one side to remove the loose stains first, and then immerse the other side. This method can efficiently remove dirt and prevent swollen dirt peeled from fins from blocking the spaces between fins.
Also Suitable for Cleaning of BOILER and Cooling Water deposition...
Scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture , To increas usable life of cleaned equipment , it is safe and effective way to remove scale deposits from all types of water-cooled and water-heated equipment. This descaler specifically formulated and developed to rapidly clean mineral scale from passages in water-cooled or heated equipment. It improves Plant Efficiency, Lowers Cost, Conserves Energy, Decreases Down-Time.
Chemically react with and decompose Calcium, Magnesium deposited Salts. Suitable for pipeline, boiler, HVAC, Heat Exhanger, Condenser, Evapourator, Chiller, Compressor and etc. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage . Fast and effctive scale remover .
- Non-combustible
- Smoke from fires is irritating
- Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
- Prevent run off water from entering drains if possible
- Non-poisonous ::: It does not contain toxic cresols or other tar oils that Require SARA Title III, Section 313 spill loss or disposal.
Non-polluting, Non-corrosive.
Uniqueness of RXSOL-54-1048-020 ::: ---
RXSOL-54-1048-020 Descaler has the ability to dissolve approximately 1.5kg of calcium carbonate scale per gallon in concentrated form. It does not need to be heated up during cleaning. The uniqueness of this Descaler allows you to clean some equipment while still in operation utilizing a minimum of your own personnel.
• Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders
• Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers
. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.
• Buildings - Chillers, Cooling Towers, Pipework
• Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps
• Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables
• Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps
• Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays
• Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators
• Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps
• Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers
• Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps
• Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers
• Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces
• Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers
Boilers
Condensers
Filters
Heat Exchangers
Kettles & Tanks
Pipelines
Pots
Reactors
Steam Jackets
Bath Rooms and Showers
Metal Processing and much more!
Applications
Automotive |
Bottling |
Chemicals |
Food |
- Closed Circuit Cooling - Dynamometers - Extruders - Molders - Radiators - Welders |
- CO2 Generators - Heaters - Exchangers - Rinse Tanks - Sterilizers and Washers |
- Dryers - Extruders - Kettles - Mixers - Reactors - Scrubbers - Vacuum Pumps |
- Condensers - Ice Machines - Kathabars - Refrigeration Equipment - Steam Tables |
Manufacturing |
Metals |
Mining |
Paper |
- Chillers - Compressors - Furnaces - Quenchers - Vacuum Pumps |
- Bearings - Conveyors - Fans - Hearth & Vacuum Furnaces - Shelters - Sprays |
- Bearings - Conveyors - Filters - Presses - Process Lines - Radiators |
- Calendar Rolls - Mill Rolls - Caustic Lines - Scrubbers - Compressors - Liquor Tanks - Pulverizers - Vacuum Pumps |
Pharmaceutical |
Refinery |
Rubber & Plastics |
Steel |
- Exchangers - Loop Systems - Kathabars - Pumps - Reactors - Stills - Sterilizers |
- Compressors - Converters - Crackers - Exchangers - Piping - Pumps |
- Banbury Mixers - Calendar & Mill Rolls - Extruders - Injection Molders - Molds - Temperature Control - Units - Throat Coolers - Towers and Tubers |
Bearings ConCast Units Generators Hearths Spangle Units Furnaces |
Textile |
Utilities |
Other Applications |
|
- Air Washers - Compressors - Condensers - Exchangers - Extruders and Towers |
- Boilers - Turbines - Transformers - Cooling Towers - Air Compressors - Hydrogen Coolers - Lube Oil Heat Exchangers |
- Ball Mills - Demisters - Evaporators - Locomotives - Absorption Units - Diesel Generators - Induction Furnaces |
Procedure-of-use: The most effective descaling is accomplished by circulation.In the case of small components,the soak method in an immersion bath can be used. If the equipment to be cleaned is contaminated by oil, grease or sludge, then pre-cleaning with DEGREASER ( RXSOL OB 1005 ) is necessary. Depending on the extent of scaling, use a solution of 2.5-10% RXSOL-54-1008-025 . The solution will have a red colour which changes to orange when 85% of the acid has been neutralized , & to colourless when the solution is totally neutralized. Whenever possible, the solution should be heated to 60°C.Neutralised solutions can be re-activated by adding more RXSOL-54-1008-025 until the red colour reappears.
Fields: Descaling of Boilers, Descaling of Diesel Engine Cooling Systems, Condenser, Pipeline collection system, Evaporators, Calorifiers, Heat Exchangers,The strength of the acid can be enhanced by adding 1part sodium chloride (common salt) to 20 parts of Descalex.If salt is not available, an acceptable alternative is to dissolve RXSOL-54-1008-025 in sea water. After use of RXSOL-54-1008-025 a 0.5% solution of Alkalinity Control in fresh water should be used for neutralization.
RXSOL-54-1048-020 is mixed with fresh water 3 to 20 percent depending on deposition of scaling.
If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonized oil, then first of all clean the system with degreaser RXSOL-10-1005. RXSOL-54-1048-020 should be mixed with fresh water to form a solution of 10-30%, depending on the extent of scaling. After using RXSOL-54-1048-020 ,
PRECAUTION :::it is essential to thoroughly rinse all metal surfaces at least once with a 0.5% solution of RXSO-20-2005 in fresh water. This solution should be circulated for 2-4 hours or until an acceptable pH value is obtained. This will neutralize any remaining acidity & passivate steel surfaces.
#AirCOOLERcleaner_supplier
#AirCOOLERcleaner_manufacturer
#AirCOOLERcleaner_Mumbai
#AirCOOLERcleaner_Chennai
#AirCOOLERcleaner_Dubai
#AirCOOLERcleaner_Muscat
After using RXSOL-54-1048-020, sense all metal surfaces with 0.5 percent of RXSOL-10-1005, at least 2-4 hour , up to neutral of PH value.
• Fast and effective scale remover.
• Soft on ferrous metals.
• Removes water scale & rust from boilers/diesel engine & other cooling system
• As well as from condensers, evaporators, & heat exchangers etc
Why Use RXSOL Descaler?
- It is a safe , economical concentrated chemical to be used on the waterside of heat transfer equipment.
-
You do not have to heat RXSOL-54-1048-020 .
RXSOL-54-1048-020 is safer for the employees to use than other acid products. -
Your equipment will be cleaned in only hours without disassembling any part of the equipment. Equipment can also be cleaned without any down time (cleaning on the run).
- Cleans down to the original surface without pitting.
- RXSOL-54-1048-020 is safe on copper, copper-nickel, bronze, brass, iron, stainless steel and rubber.
- RXSOL-54-1048-020 will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program.
-
Removing the scale build up allows your equipment to operate more efficiently with less down time.
Air Cooler Cleaner Sea Water Side Scale Remover manufacturer and supplier Exporter.